“The Gold Series BIBO Camtain is a winner for our pharmaceutical applications. It is way ahead of the curve of anyone in the dust collection industry. The results from the potent compound surrogate test are very positive. Nice work!”

Project Engineer, Major Pharmaceutical Company

Gold Series Camtain™ on Pharmaceutical Applications
Bag In Bag Out (BIBO) safe change containment systems are available on both the cartridge access doors and dust discharge system underneath the collector. Farr has BIBO dust collectors on pharmaceutical applications in the USA, Canada, and Europe. Farr has named its BIBO dust collection system the Gold Series Camtain™. Camfil Farr is the parent company of Farr APC and is the world leader in HEPA BIBO filtration systems.

Benefits of the Gold Series Collector
  • High entry cross-flow inlet eliminates upward can velocities that can hold fine powder up in the filters reducing re-entrainment of the fine particles.
  • Vertically arranged filters shed all the particulate—vs. horizontal filters which allow the dust to build on top of the filter.
  • High efficiency filters stop 99.99% at 0.5 microns (µ) of the dust!
  • Special treated filter media repels the fine particulate for lower pressure drop and long filter life.
  • Gold Cone provides 25% more media for long service life.
  • BIBO door has camlock sealing action and is hinged to easily move out of the way.
  • Filters are sealed via camlock action making it easy to work through the bag.
Safety Considerations

Two key concerns come into play with pharmaceutical dusts—first is the hazardous nature of the compound as it relates to direct human exposure, and the second is its explosive nature. With the first issue you must determine if BIBO containment systems are necessary to protect the workers. In most cases Farr recommends a HEPA secondary polishing system. With HEPA backup systems after the dust collector, recirculation of the filtered air back into the HVAC system is gaining in popularity in the pharmaceutical industry.

Explosions are a major concern on most pharmaceutical compounds. Steps such as explosion venting, suppression, and isolation systems may be required depending on the explosion rating of the dust and the location of the collector. When explosion vents are required, they must be vented to the outside by either placing the collector outside, or ducting the vent exhaust a short distance through a wall to the outside. Farr recommends that an independent PE specifies explosion protection as it relates to recommendations in NFPA, Factory Mutual or ATEX.

The Only Potent Compound Surrogate Tested Dust Collector
The Gold Series Camtain BIBO door and BIBO dust discharge system has been personnel exposure tested with lactose as the surrogate dust for the potent pharmaceutical compound. Over 75 air quality and swab test points were taken during multiple change outs of the dust and filters. This was performed by an independent testing firm (Broadspire) who is certified by a major pharmaceutical company for potent compound sample testing. The Gold Series Camtain is the only potent compound tested dust collector on the market today, and can handle your toughest applications. Full test report data is available upon request.
The BIBO filter change process—all camlock filter change—on knobs or threads


© Copyright 2008, Farr Air Pollution Control